METHODS OF RETAINING REMOVABLE DENTURES USING DENTAL IMPLANTS
Downloads
Objective: This article presents a review of current methods for retaining removable dentures using dental implants. Methods: The main types of attachment systems are discussed—ball attachments, clasp and lock mechanisms, bar designs, and magnetic systems. Their biomechanical characteristics, indications, advantages, and limitations in clinical practice are analyzed. Special attention is given to the role of digital CAD/CAM technologies in the planning and fabrication of implant-supported dentures, which enhance positioning accuracy, durability, and patient comfort. Results: It is shown that the use of implants for denture retention significantly improves stability, function, and quality of life, especially in cases of severe alveolar ridge atrophy. Novelty: Special attention is given to the role of digital CAD/CAM technologies in the planning and fabrication of implant-supported dentures, which enhance positioning accuracy, durability, and patient comfort.
T. Albrektsson, P. I. Brånemark, H. A. Hansson, and J. Lindström, “Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man,” Acta Orthop. Scand., vol. 52, no. 2, pp. 155–170, 1981, doi: 10.3109/17453678108991776.
C. N. Elias, J. H. C. Lima, R. Valiev, and M. A. Meyers, “Biomedical applications of titanium and its alloys,” JOM, vol. 60, no. 3, pp. 46–49, 2008, doi: 10.1007/s11837-008-0031-1.
I. Denry and J. R. Kelly, “State of the art of zirconia for dental applications,” Dent. Mater., vol. 30, no. 8, pp. 893–902, 2014, doi: 10.1016/j.dental.2014.05.012.
M. Revilla-León and M. Özcan, “Additive manufacturing technologies used for processing polymers: Current status and potential application in prosthetic dentistry,” J. Prosthodont., vol. 26, no. 2, pp. 146–158, 2017, doi: 10.1111/jopr.12481.
P. Svanborg, V. Stenport, and A. Eliasson, “Fit of cobalt–chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks,” J. Prosthet. Dent., vol. 120, no. 4, pp. 596–602, 2018, doi: 10.1016/j.prosdent.2017.11.012.
J. W. Nicholson, “Titanium Alloys for Dental Implants: A Review,” Prosthesis, vol. 2, no. 2, p. 11, 2020, doi: 10.3390/prosthesis2020011.
D. G. B. de França, M. H. S. T. Morais, F. D. das Neves, and G. A. S. Barbosa, “Influence of CAD/CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses,” J. Prosthet. Dent., vol. 113, no. 1, pp. 22–28, 2015, doi: 10.1016/j.prosdent.2014.07.010.
V. Rutkunas, H. Mizutani, and H. Takahashi, “Influence of attachment wear on retention of mandibular overdenture,” J. Oral Rehabil., vol. 44, no. 7, pp. 561–568, 2017, doi: 10.1111/joor.12515.
M. Andreiotelli, W. Att, and J. R. Strub, “Prosthodontic complications with implant overdentures: A systematic literature review,” Int. J. Prosthodont., vol. 23, no. 3, pp. 195–203, 2010.
D. Schneider, F. Schober, P. Grohmann, C. H. F. Hammerle, and R. E. Jung, “In vitro evaluation of the accuracy of fit of CAD/CAM milled bars for implant-supported overdentures,” Clin. Oral Implants Res., vol. 27, no. 6, pp. 738–745, 2016, doi: 10.1111/clr.12630.
J. M. Thomason et al., “Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients--The York Consensus Statement,” Br. Dent. J., vol. 207, no. 4, pp. 185–186, 2009, doi: 10.1038/sj.bdj.2009.728.
S. H. Chaware and S. T. Thakkar, “A systematic review and meta-analysis of the attachments used in implant-supported overdentures,” J. Indian Prosthodont. Soc., vol. 20, no. 3, pp. 255–268, 2020, doi: 10.4103/jips.jips_368_19.
R. E. Jung et al., “Computer technology applications in surgical implant dentistry: A systematic review,” Int. J. Oral Maxillofac. Implant., vol. 31, no. Suppl, pp. 30–44, 2016, doi: 10.11607/jomi.2016suppl.g1.
J. S. Feine, G. E. Carlsson, M. A. Awad, J. P. Lund, and R. Tomasini, “The influence of implant-supported overdentures on the health-related quality of life of edentulous patients: A systematic review,” J. Dent. Res., vol. 81, no. 1, pp. 1–10, 2002, doi: 10.1177/154405910208100101.
T. Joda, M. Ferrari, G. O. Gallucci, J.-G. Wittneben, and U. Brägger, “Digital technology in fixed implant prosthodontics,” Periodontol. 2000, vol. 73, no. 1, pp. 178–192, 2017, doi: 10.1111/prd.12164.
Copyright (c) 2026 Babayev Elmar Elman, Gurskaya Narmina Azad, Ibragimov Elshad Agaveli